Voltage Regulator 673.3702
1 Installation
1.1 Remove dust and rust from the place of regulator installation. Put the regulator on the bolt mass and fasten it firmly.
1.2 Disconnect regular regulator with brush unit outlets.
1.3 Connect «+» and «Ш» of regulator with «+» and «Ш» of brush unit using connective cables.
Note: «+» outlet in brush unit which is solid with regulator is the outlet connected to the three additional generator diodes.
1.4 Turn the switch to one of the three positions depending on the need of exploitation.
2 Voltage Positioning
2.1 «14,2» position is intended for operation at outside temperature between 0ºС and 20ºС, without additional devices which can make the voltage lower;
2.2 «14,9» and «15,2» positions are intended for operation at outside temperature lower than 0ºС, or when additional devices which can make the voltage lower are connected.