While installation of indicator the battery must be switched OFF! |
1. Choose convenient and visually controlled place for indicator installation.
2. Make an opening with diameter 52 mm and fix indicator case inside it using a nut.
3. Connect wires with indicator terminals using 6.3 sockets:
minus of power supply to “-” of indicator;
plus of power supply to “+” of indicator;
signal of terminal D+ of generator to “D+” of indicator;
plus of side lights to “” of indicator.
Attention! Incorrect connection is prohibited!
Operation description:
Time indication will start as soon as the power is supplied.
Time is calculated only when power is supplied on the D+ terminal of indicator.
The fact of start is proved by blinking point on the right side.
When power supply is stopped, final values are saved in the indicator memory. Error is 1 second only.
Nullifying
To nullify indicator memory connect “RESET” terminal of indicator with mass for a short time during operation mode.